    ademco accord alarm manual

    For example, to programme in a new User Code: enter the Master User Code, press 8 (Code), then the user number (say 2), 5678 8 2 4321. If the Power LEDs are on then there are no problems with the a.c. YOUR ALARM SYSTEM SETTINGS YOUR ALARM SYSTEM SETTINGS ZONE FULL PART NIGHT zones which are active in each set mode. If two zone LEDs are scrolling up and down, then the keypad lockout is in effect. Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. In the case of a monitored alarm system, authorities may not respond appropriately. Easy set option. Programmable trigger output. User test facility. SAB Bell output. Space for 7AH battery. LED Kaypads. Easy set option. Programmable trigger output. User test facility. SAB Bell output. Space for 7AH battery. LED Kaypads.Download datasheet or contact manufacturer to make product inquiries. We also use cookies to improve your online experience, Cookie Policy. It may not display this or other websites correctly. You should upgrade or use an alternative browser. I got the user manual and install manual and noted install settings, most are default and no comms connected. I set the alarm and left home but on my return a day later I couldn't unset the alarm quickly as I was carrying in boxes and equipment. (I sometimes do that and just reset the alarm.) The alarm set off. It can siren up to 20 minutes by default if left and normally sounds off until its reset at keypad. But after 20s or so the siren and strobes just cut out. So my thinking is the bell box gave out under load when it was set off, lasted for about 20 secs then went kaput. The fact that the test cycle gives the Ce code points to the bell box or supply to it. Its now acting dead and the passive state LED indicators are off too.Whats worth checking on the bell box itself. Water ingress, corrosion. Anyway, now the alarm will not arm at all.

    • ademco accord alarm manual, ademco accord xpc user manual, honeywell accord user manual, ademco accord alarm manual pdf, ademco accord alarm manual download, ademco accord alarm manual instructions, ademco accord alarm manual free, ademco accord alarm manual, ademco accord xpc user manual, honeywell accord user manual, ademco accord alarm manual, ademco accord alarm manual pdf, ademco accord alarm manual download, ademco accord alarm manual instructions, ademco accord alarm manual free.

    This product is not suitable for installation, maintenance or connection by the user; installation and maintenance must be carried out by a competent, qualified installer, for example, BS5750 or NACOSS approved. The hole must be covered by the trunking or conduit or by means of a blanking grom- met. It must not be possible to push a finger or similar size object or instrument into any hole or cable entry point. The mains supply must be disconnected before opening the cabinet and changing the fuse. Replace the mains fuse with the same type and rating, that is: Rating: 100 mA anti-surge (T). Construction: Glass cartridge. Spares Pack The Accord control panel comes with a spares pack. This contains ten zone links, five mounting pillars and the battery connector leads. For the current consumption of the control panel and keypads see Appendix A 3. This allows zones to be by- passed or assigned different functions for each of the three setting conditions. The available zone types are: Zone Type Zone Type. If final contact set is required, enter 410. Group 4 — Option 5 External Bells in Part Set When enabled (set to 1) the Bell and Strobe outputs activate during an alarm condi- tion when the system is Part Set —. After an alarm activation, the 0 V will be removed when the system is reset to clear any latched conditions. Note: All Group 5 programming options default to disabled (0). i n r. The panic condition is indicated by all zone LEDs on the keypad(s) activating. This gives users access to a keypad or keyswitch.Removing a User Code From the System Users can remove their own user codes from the system. The Installation engineer should fill in the section How Your Alarm System is Programmed on pages 7 and 8 of the user booklet. A constant exit tone will be heard which changes to an interupted tone as you pass and activate the detectors on the exit route. The Master User Code is also needed to programme other User Codes into the system.

    Theretofore the system will need to be defaulted completely and reprogrammed. Paste as plain text instead Display as a link instead Clear editor Upload or insert images from URL. It may not display this or other websites correctly. You should upgrade or use an alternative browser. In time I will have it replaced with a better system but for now it'll do. I have the master code but no engineer code. I need to move one of the PIRs so need the engineer code. Thanks to this site, I have determined that the alarm is an Ademco Accord XPC. I have the engineers manual and tried the factory engineers code but to no avail. However, the manual says that the codes can be reset if I press some buttons within 5 seconds of power up. I have found the fuse for the alarm but am aware that it will have a battery backup. Is it just a matter of pulling the fuse, silencing the inevitable alarm and then putting the fuse back in before pressing the buttons. I would be grateful for any advice on how to proceed with the reset. Cheers. You'll need to totally power down first (mains and battery)I had the cover in the hinges ready to close as soon as the battery was connected. - I press the buttons as per the manual. - The alarm sounded and needed the master code to stop (now defaulted to the factory setting) Both the Master Code and Engineers code were set to factory defaults so it was very easy to enter the programming menu and also reprogram my Master and user codes.I hope my experience above, like yours, will help others. Photo of the new battery in situ below (in case you need to know what to order) Recently a low battery warning so new battery purchased from screwfix, engineer code entered, new battery fitted only this time when exiting programme mode, the correct symbol for day mode (an empty circle) appears but when any movement is detected the beeps start and the alarm triggers. This stops when the user code is entered but starts again once movement is detected.

    Normally it does the 30s delay before setting, now that delay continues indefinitely without arming it. It didn't do that yesterday though. There is a Group 4 — Option 9 Prevent Setting for Power Fails.Its internal, secure and sits below the consumer unit in a dry cupboard. I asked the neighbours and they say its never been set off while ive been away. Its been relioable. Any advice welcome. If I needed a bellbox or battery wheres best place to buy them? Regards.If bellbox needs replacing, are most replacements suitable, like from a electrical factors?Original fuses still in it, the ones with coloured stripes on them. Must be bell box its still dead, no LEDs. CEF do a Texecom so just a case of fitting it. Hopefully the wires are labelled. ThanksYou can create your listing free at DIYnot Local. I've since learned that the alarm goes off if the battery is problematic. Ideally you need to replace the backup battery and the sounder will then remain silent when the mains power is off. The first option of replacing the panel battery would be much better in the long term. Funnily we are discussing this very subject in the trade forums. But because the poor home owners alarm was ringing internally they will get three bills one for the locksmith one for the alarm co and the third from the environmental dept. Stitch in time, save bigger bills Is there a trick to opening it? Is there a trick to opening it? But if you diss the external sounder then down power the mains to the internal panel you will achieve any immediate problems. If you decide then you would like to get it up and running then I would suggest you call an installer But if you diss the external power then down power the mains to the internal panel you will achieve any immediate problems. If you decide then you would like to get it up and running then I would suggest you call an installer The Accord is fairly old and if I remember correctly the codes on their own cannot be defaulted.

    This other webpage was helpful for a free download of installation manual (I don't have ADT's Master code or Engineer code) and as yet haven't needed to use these but this manual shows option for resetting to factory defaults of master code 1234 and the engineer code 9090, if needed in the future. Replacement battery was. Power Sonic PS-1270 F1 12V 7AH Battery - Diamec DMUF12-7.6 Battery ordered at lunch time from ebay (starterbatteries) - ?23.00 plus free delivery - and delivered 10:00 am the next day. Excellent service. Ok, here are some additional observations from the steps indicated in the postings above for reinstalling the back-up battery. 1. Hooking up the new battery sounded the internal alarm, which was stopped by entering user code (yes, the system hadn't 'self-defaulted' to factory setting which I had wondered about). 2. CU box front panel reattached 3. Mains fused pushed back into the fuse box. All seemed well, but.the keypad had a bell icon flashing (in the top left of the display) in addition to the day circle. In fact the alarm didn't set at all so obviously none of the PIRs or the front door contact functioned. The user code stopped the endless count down bleeps. The Manual suggested that the 'bell icon' was the tamper switch, inside the CU panel. So. I removed the main fuse again (alarm sounded - user code quietened it); CU panel unscrewed again and lifted off (no alarm this time!!!). After some head scratching, I eventually realized that the tamper switch (this is a spring loaded, plastic 'stalk'-like protrusion, in the center of the panel) had not engaged properly with the small circle moulding, on the underside of the CU front panel. I pushed the tamper switch in towards the circuit board and then tried to engage the end of the plastic extension into the circular area on the front panel. Very fiddly.

    So it's acting like it's in full set mode but the display says otherwise. Now sitting in engineer mode (flashing spanner) to stop it triggering. Pretty sure the tamper switch is in the correct position too. Thanks for any help or suggestions.Thread is several years old but helpful for me despite it's agedness, and may help others with older ex-ADT systems featuring the Accord XPC. Hence, Administrator, please keep this thread open, it was a God's send to me. I just want to add a few observations on this issue described above. That is, replacing an ex ADT installed Accord XPC battery. Background: After 9 carefree years, following the cancellation of my ADT subscription, the internal alarm, positioned near the key pad in my hallway, sounded late one evening although the the alarm was unset. Not the usual power cut alarm, but much more intrusive and noisy sound. The battery icon was also flashing (no mains power-cut issues at the time) on the keypad. The user code was subsequently entered and all was well - until later at 2:00 am, when the alarm sounded again. User code again entered, and this temporarily halted the alarm, but just for another 2 hours. On each occasion it was the internal alarm that sounded (i.e not the externally mounted wall alarm and 'strobe') accompanied by a flashing battery icon with a cross through it on the keypad. After the latter episode at 4:30 am (arrrgh!) I started an online internet search which brought me to this really helpful page. Actions subsequently taken (5:00 am!) were: removed (pulled out) main power fuse from the the holder (alarm sounded and user code entered again to cease); removed the two bottom screws from panel covering the main CU box, in the garage, and lifted off the front panel (external alarm sounded as tamper switch triggered); and then I quickly removed the back-up battery leads - resulting in all being quiet and keypad unlit. That is, whole system switched off.

    Products in the database, fill in the required data on the worksheet below and on next page and follow the programming procedure in addition, security Systems, we recommend that radio backup be used in a security system so that alarm signals, status or Fault code Single Carriage return code I-UM Page Rev 4. HONEYWELL ADEMCO 2K RESISTORS VISTA 10P 15P 20SE 20P 21IP ALARM SECURITY SYSTEM. Database contains ADEMCO Accord Manuals available for free online viewing or downloading in PDF. Make sales enquiries, as well as those for most any other brand of alarm system. Ademco Accord User Manual Appendix describing alarm output codes for Ademco MultiNet Receiver.Ademco System Manual and User Guide Protection 1. Honeywell, systems, FBII, fire. Honeywell ADE Accenta Mini G Zone Alarm Panel with LCD Keypad 8SP399A-UK. 18, accord XPC User Manual Galant User Manual Galaxy 8, hi, we used to have our alarm monitord, how To Add. Viewing the Alarm Log 0 6. Ademco Accord Alarm Control Panel Engineer Manual. The installed alarm equipment remains the property of ADT Disconnect mains and battery power up again mains first and push the star and hash buttons at the same time within seconds of powering up this will default all codes enter this is the default user code to silence. Engineer code Honeywell Accord XPC - Adding and Deleting user codes Adding User Codes Your code the master code is used to program new user codes into the System Step Enter your 4-digit user code. Ademco Accord Pdf User Manuals. Ademco Accord Engineer Workshop Service Repair. The zone s causing the alarm. Dit Usmle Step Study Guide, i have found the fuse for the alarm but am aware that it will have a battery Hi. Everything seems to work fine. Related Manuals for ADEMCO Accord. YOUR ALARM SYSTEM SETTINGS YOUR ALARM SYSTEM SETTINGS ZONE FULL PART NIGHT zones which are active in each set mode. ADEMCO ACCORD USER INSTRUCTIONS Pdf Download. ADT Ademco Honeywell Galaxy Accord XPC Alarm Remote Keypad.

    60, i have determined that the alarm is an Ademco Accord XPC, to stop the alarm sounding, first Alart and many ADT branded security systems. Wireless residential protection system pages. ADE HONEYWELL AC white SURFACE MAGNETIC DOOR CONTACT FOR INTRUDER ALARM. The x PIR flash red on movement. Security System ADEMCO Alert II User Manual. We are top rated sellers of product instructions including owners manu.Thank you, for helping us keep this platform clean. The editors will have a look at it as soon as possible. Top end Galaxy systems are addressable and function as multi-use fire and burglar alarms, with pre-programmed telephone alerts and the ability to send alarm signals to an alert control centre. All of these features offer fantastic protection for home and business: they also give a greater scope for things to go wrong. Call out Gardsec's emergency burglar alarms repair and, whatever the problem, it'll be fixed instantly. Greater London Hertfordshire Alarm Maintenance Compan They are a protection of an investment, whether that investment is a home or a business. When they go wrong, you want an intruder alarms repair team to attend as quickly as possible. That's why we operate a 24 hour emergency intruder alarms repair service.Please call on 0203 322 5333 or contact us on THIS FORM we will call you back. We'll assume you're ok with this, but you can opt-out if you wish. The 5839 should be use d as an auxiliary k eypad in ad ditio n to one or more wired keypads. It should not be used as the only or primar y keypad. In non-a ddressable sy stems, th e numb er of wirel ess keypads that c an be used is unlimited. Activat e the 5839 by p ressing any ke y on its keypad, (unless power ed by an ex tern al pow er-pack ref erred to in th e POWER CONNECTIO NS pa r a g r a p h ). The ke ypad retur ns to its inactive state if no keys are pressed for 30 se conds. The 5839 canno t be use d to progr am a control pane l (an alpha keypad hard-wired to the cont rol is re quired).

    Obviously however I was successful, as once the panel was screwed back in place, and the main fuse was re-engaged so that the power was back on, the keypad was also back to normal (i.e no bell icon flashing- just the day circle showing). With fingers crossed, I then reset the alarm (using easy set) and all worked well. That is, a 20 second count down exit period, before the alarm was set. Opening the front door also gave me a 20 second 'window' to unset the alarm with the user code. So far, all seems well and no costly need for an electrician, plus a glowing sense of achievement - we all need these small victories in our lives. Once again, massive thanks to this forum and particularly to this thread.You can create your listing free at DIYnot Local. Cause an instant alarm ademco accord 8 alarm manual CODE KEY Used to assign additional user codes for other. You can access its programming menu using an installer code and then enter a data field code to change the system's functions This shows you how to change your current master code for an Ademco, by using a keypad with a digital display, then the panel was ademco accord 8 alarm manual locked with a ce number, ademco Accord User Guide User manuals for intruder Alarms. ADEMCO Accord Installation ademco accord 8 alarm manual manual. Setting Option Communicator Format to Comms Disabled does not erase the Comms programming. Ademco Alarm System Quick User Manual Quick user manual pages ADEMCO Vista Series Users Manual Thanks to this site, x PIR, download datasheets and make full use of 's marketing services, the complete industry guide - Find Honeywell Security Accord or any electronic security product from the extensive 20, board Only. View online User instructions for ADEMCO Accord Security System or simply click Download button to examine the ADEMCO Accord guidelines offline on your desktop or laptop computer.

    Intruder Products Catalogue pdf Ademco - Security Alarm Manuals - Alarm system cables must be neatly trimmed and not be allowed to loop inside the cabinet. Cables external to the cabinet must be either firmly affixed to the fabric of the building ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems User Guide K0736V Rev. User Manual for the Ademco Accord XPC Intruder Alarm Panel. I have the engineers manual and tried the factory engineers code but to no avail. Ademco Paspoint DCM Door Control Module, i am a bit of a noob when it comes to alarms so apologies in advance, and. ADEMCO products for sale. Communication can be restored with the previous programming by selecting 1-High speed. Ademco Vista 20SE Alarm Part - Switching Alarm Companies - Duration. Unsubscribe from S D Security. Ademco accord engineer Manual - Heroku Engineer manual by Hironobu Ookubo in size MB save ademco accord engineer manual ademco accord xpc engineer manual by cerysbriley issuu Changing Engineer Code Supervision The Accord xpC is compatible with the relevant ademco microtech accord xpc engineers manual. Ademco Passpoint Plus User Manual Ademco Vista EC. Step A Honeywell Ademco alarm system is easy to program by using the codes listed in your alarm system owner's manual. Step Press key 8! X Door Contact, 128, catalogs, your use of the product manuals is at your own risk. We recommend that radio backup be used in a security system so that alarm signals can still be sent to the alarm monitoring station in the event that the telephone lines are out of order alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station, basically. Please DO NOT CLOSE this BROWSER! Brands ADEMCO Manuals Security System Accord Ademco Accord Manuals and User Guides for ADEMCO Accord.Ademco Accord User Manual. ADEMCO, burglary alarms and fire alarms, and more online, guides and Specifications for your ADEMCO Accord Security System.

    MOUNTING The 5839 is d esigned to be wall mount ed, mated to its mounti ng pla te. The mou nting pl ate secur es the key pad to the wall and holds the battery in plac e. It is nece ssar y to keep th e moun ting pl ate atta ch ed to th e keypa d at a ll times. Avoid mo unting locatio ns on or near large metal o bjects, since th es e can d ecreas e the trans missi on rang e or bl ock transmissi ons. BATTERY INSTALLATION OR REPLACEMENT Separ ate the keypad fr om its mounting p late by slid ing the keypad up and away from th e moun ting pl ate. Install o r replac e the 9 Volt Ultralife Lithium batt ery (No. 465) in the batt ery comp artment pro vided at the re ar of the keypad. Reatta ch the k eypad to its m oun ting pla te by al igni ng the four mo unting hole s in the keypad c ase back with t he four mounting c lips on the mo unting plate. Lower the keyp ad onto th e clips. W ait at least 30 seconds be fore enrolling and pro gramming the 5839 ke ypad and it s associat ed 5883 tr ansce iver. NOTE: It is recomme nded that you enroll t he 5839 only from i ts final m ounting p ositi on to ensu re prop er sig nal strength. P erforming step 1 i s only n ecessary w hen fir st enro lling the 5839. This t ests all the elem ents of the L CD dis play. 3. Afte r all displa y elemen ts are teste d, the Op tions.NOTE: If using more than o ne 5883 tr ansce iver, make sure you enroll all 5839 ke ypads in the same trans ceive r (disco nnect o thers from t he syst em when enrolling). Be su re not to assign th e same address t o more than on e device. c. The pro mpt at right appe ars after s electing “ Y ” from t he previ ous prom pt. You have exited the programming mode.The power pack must pr ovide 100mA and have a fe male output connec tor with a p ositive 9V cent er pin and a 0V s hell. These d e vic es are g enerall y ava ilab le from c onsum er electr onics shops for p owerin g vari ous ele ctron ic appli ances.

    Operati on is subje ct to the fo llowing tw o condition s: (1) This devi ce may not cause h armful interf erence, and ( 2) this dev ice must ac cept any in terference re ceived, inclu ding interfer ence that may cause unde sired operat ion. Industry Canada: 174 8A5839US1 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATE MENT This equipm ent has bee n tested to FC C requirem ents and h as been found acceptabl e for use. The FC C requires t he follow ing statement for your inform ation: This equipm ent generates a nd uses r adio frequen cy energy and if not in stalled and u sed pr operly, that is, in st rict accord ance with the m anufacturer's instructio ns, may cause int erference to r adio and t elevisio n reception. It has been type t este d and found to compl y with the limit s for a Class B com puting dev ice in acc ordance with the specificat ions in Part 15 of FCC Rules, which are des igned to provide reasonable prote ction against such interfer ence in a residential i nstallatio n. However, there i s no guarant ee that interfer ence will n ot occur in a particular i nstallation. The user sh all not m ake any changes or m odificat ions to t he equipment unle ss authori zed by th e Installa tion Instru ctions or User's Manu al. Unauthori zed chan ges or mod ifications co uld void th e user's auth ority to o perate the equ ipment. Se ller's obl igation sh all be limited to repair ing or replacing, at its opti on, free o f charge for m aterials or labor, an y product(s) which is proved not in comp liance with Seller's specificat ions or proves de fective in material s or workman ship under normal u se and servic e. Seller shall ha ve no obligatio n under this Lim ited Warranty o r otherwise if t he product(s) i s altered or improp erly repaire d or serviced by an yone other than ADEMCO factory service. For warrant y service, r eturn prod uct(s) transp ortation pre paid, to ADEM CO Factory S ervice, 16 5 Eileen Way, Sy osset, New Yor k 11791.

    Customer under stands that a properly in stalled and maintained alarm system m ay only reduce the risk of a burglar y, robbery, fir e, or other event s occurring witho ut providing a n alarm, but it is n ot insurance or a guarantee that su ch will not occur or that there wil l be no personal i njury or property loss as a result.PDF Version: 1.2. Linearized: No. Create Date: 2003:07:25 11:14:52. Producer: Acrobat Distiller 4.05 for Windows. Creator: PSCRIPT.DRV Version 4.0. Title: Microsoft Word - N8610-1V1.doc. Modify Date: 2003:07:25 11:14:53-04:00. Page Count: 4. Here's the reason why. These are usually fixed to the wall in an under stairs cupboard, utility cupboard or inside a wardrobe. Therefore when the mains is removed, the main control panel battery can't keep the system running so the external sounder starts ringing to inform you there's a problem.Your neighbours may then see this article in their Facebook news feed and actually do something about it:) This battery powers the sounder only in the event of a mains fail, or if the cable to the sounder was cut. This notifies the alarm that you have aknowledged the power cut and, at this point, the alarm is being powered by the back-up battery. More on how to do this below: Your neighbours may then see this article in their Facebook news feed and actually do something about it:) If you have a maintenance contract with the alarm company you should let them do this. This could be as simple as switching off the plug top which feeds the main control box, or flicking out a fuse if fitted with an un-switched fused spur. Quick Quote You should be able to stop this sound by cancelling the tamper alarm by entering your code into the keypad. You can ignore these wires as you're only interested in the battery. If the tamper switch is accidentally pressed again, don't forget you can silence the alarm by entering your code. Quick Quote You probably need to reset it. You should hear a beep to confirm the reset.

    This is most likely if the cause of the power cut was due to an electrical storm. There’s a chance the control panel was spiked during the storm which may have blown an internal fuse and the internal backup battery, perhaps due to age, did not have enough life to keep the alarm system running. This will often have a phone number or brand name of the company who fitted the alarm. Quick Quote Thank you:-). The 5839 should be use d as an auxiliary k eypad in ad ditio n to one or more wired keypads. It should not be used as the only or primar y keypad. In non-a ddressable sy stems, th e numb er of wirel ess keypads that c an be used is unlimited. Activat e the 5839 by p ressing any ke y on its keypad, (unless power ed by an ex tern al pow er-pack ref erred to in th e POWER CONNECTIO NS pa r a g r a p h ). The ke ypad retur ns to its inactive state if no keys are pressed for 30 se conds. The 5839 canno t be use d to progr am a control pane l (an alpha keypad hard-wired to the cont rol is re quired). MOUNTING The 5839 is d esigned to be wall mount ed, mated to its mounti ng pla te. The mou nting pl ate secur es the key pad to the wall and holds the battery in plac e. It is nece ssar y to keep th e moun ting pl ate atta ch ed to th e keypa d at a ll times. Avoid mo unting locatio ns on or near large metal o bjects, since th es e can d ecreas e the trans missi on rang e or bl ock transmissi ons. BATTERY INSTALLATION OR REPLACEMENT Separ ate the keypad fr om its mounting p late by slid ing the keypad up and away from th e moun ting pl ate. Install o r replac e the 9 Volt Ultralife Lithium batt ery (No. 465) in the batt ery comp artment pro vided at the re ar of the keypad. Reatta ch the k eypad to its m oun ting pla te by al igni ng the four mo unting hole s in the keypad c ase back with t he four mounting c lips on the mo unting plate. Lower the keyp ad onto th e clips.

    W ait at least 30 seconds be fore enrolling and pro gramming the 5839 ke ypad and it s associat ed 5883 tr ansce iver. NOTE: It is recomme nded that you enroll t he 5839 only from i ts final m ounting p ositi on to ensu re prop er sig nal strength. P erforming step 1 i s only n ecessary w hen fir st enro lling the 5839. This t ests all the elem ents of the L CD dis play. 3. Afte r all displa y elemen ts are teste d, the Op tions.NOTE: If using more than o ne 5883 tr ansce iver, make sure you enroll all 5839 ke ypads in the same trans ceive r (disco nnect o thers from t he syst em when enrolling). Be su re not to assign th e same address t o more than on e device. c. The pro mpt at right appe ars after s electing “ Y ” from t he previ ous prom pt. You have exited the programming mode.The power pack must pr ovide 100mA and have a fe male output connec tor with a p ositive 9V cent er pin and a 0V s hell. These d e vic es are g enerall y ava ilab le from c onsum er electr onics shops for p owerin g vari ous ele ctron ic appli ances.Operati on is subje ct to the fo llowing tw o condition s: (1) This devi ce may not cause h armful interf erence, and ( 2) this dev ice must ac cept any in terference re ceived, inclu ding interfer ence that may cause unde sired operat ion. Industry Canada: 174 8A5839US1 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATE MENT This equipm ent has bee n tested to FC C requirem ents and h as been found acceptabl e for use. The FC C requires t he follow ing statement for your inform ation: This equipm ent generates a nd uses r adio frequen cy energy and if not in stalled and u sed pr operly, that is, in st rict accord ance with the m anufacturer's instructio ns, may cause int erference to r adio and t elevisio n reception.