    ademco 685 installation manual

    Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: For minimum protection a smoke detector should be installed outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit, including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or in garages is not normally recommended. For additional protection the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages. Smoke could be blocked by the closed door.This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station). SIA Installations: The VISTA-21iPSIA is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction. The VISTA-21iP is not certified as SIA-compliant, but can be programmed for False Alarm Reduction. To program for False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields. NOTE: Throughout this manual, device model numbers are ADEMCO model numbers unless otherwise noted. Optional, detects external sounder wiring short (when in alarm) or open (when bell is off); causes a trouble condition, keypad display, and sends a report to the central monitoring station, if enabled. Optional, for wireless systems detects a condition that may impede proper RF reception (i.e.

    • ademco 685 installation manual, ademco 685 installation manual pdf, ademco 685 installation manual download, ademco 685 installation manual instructions, ademco 685 installation manual free.

    Product availability, at the moment, is in flux. If you order today, depending on the product, there may be a significant delay in shipping it to you. We apologize for any delays, and assure you that products will be shipped as soon as we can get them. Before COVID, we had significant stock of nearly every popular product that we sell. But demand has outpaced our supplier's ability to meet it, and has exhausted the stock we had purchased to meet increased demand during the government-mandated lockdowns. If you need the product right away, it is unlikely we will be able to accommodate you. For that we apologize. We ask for your patience as we all navigate this unique situation together. Be nice to our employees, they are doing their best to answer your questions and get your product to you as quickly as they can.If you are here to get product quickly because you are unable to get the product at your usual supplier, rest assured, we are also out of the product and won't be able to fulfill your order in a timely manner. Like our end-users, we will be delivering products as soon as we get them in. For the purpose of improving our site, we’d like to know if you are one of the following: Honeywell also don't sell the extra clips for the panels either. You could move the 21iP to the middle of the control panel to mount the receiver above as shown in the receiver install guide, but I'd say it's easier to just mount it remotely. I hope this helps and let me know if you have any questions. I am installing a 5881 into my 21ip cabinet. I must have the wrong clips because the 21ip won’t line up with the holes. What clips do I need and can I buy them from you ? If you did, it would show 'Disarmed Ready to Arm' when the system is disarmed. I don't have monitor services. It was installed by Camel Technology and they want a service charge to come and change this and I'm sure we could do it ourselves if we knew how. Recommendations For Smoke And Heat Detectors.

    Before installing the cabinet's contents, remove the metal cabinet knockouts required for wiring entry. Do not remove the knockouts after the circuit board has been installed. 1. Hang two short mounting clips (provided) on the raised cabinet tabs (see Detail B). 2. a. Insert the top of the circuit board into the slots at the top of the cabinet. Make sure that the board rests on the correct row (see Detail A). b. Swing the base of the board into the mounting clips and secure the board to the cabinet with the accompanying screws (see Detail B).Make sure that the board rests on the correct row of tabs. b. Swing the base of the board into the mounting clips and secure it to the cabinet with the accompanying screws. c. Insert the top of the control's board into the slot in the clips and position two clips at the lower edge of the board. d. Swing this board into place and secure it with two additional screws. 2. Insert grounding lugs (supplied with the receiver) through the top of the cabinet into the left-hand terminals of the antenna blocks (at the upper edge of the receiver board) and secure them to the cabinet top with the screws provided (see Detail B). 3. Insert the receiver's antennas through the top of the cabinet, into the blocks' righthand terminals, and tighten the screws. This control panel can meet these requirements without using a supplementary power supply, provided that the panel’s auxiliary power and bell output currents are limited as indicated below. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will fit inside the cabinet.) This assists the control panel in recharging the battery when AC is restored. IMPORTANT: The panel will not power up initially on battery power only. The following are examples of good earth grounds available at most installations.AC Power Outlet Ground: Available from 3-prong, 120VAC power outlets only.

    , jamming or other RF interference); causes keypad display, and sends a report to the central monitoring station (if trouble reporting is enabled). This allows site maintenance independent of central station monitoring, and modification to sites globally via the Internet. Also see Internet Reporting below and Internet Connection on the next page.See Expander Module Addresses table in Wiring section and set addresses accordingly. Use any combination of 4204, 4229 and or Powerline Carrier Devices. Can be used to reset 4-wire smoke detectors. Provides access to the system via on premises or off-premises phones for arming, disarming, etc., plus control of relay outputs and Powerline Carrier devices. Use ADEMCO UVS or Eagle Model 1250; can be used in conjunction with an output trigger to permit voice dialog between an operator at the central station and a person at the premises. Alternatively, the AVS system can be used to provide AAV via phone line. Rechargeable (sealed lead-acid type) 12VDC, 4AH minimum. Plug-in 120VAC transformer, ADEMCO 1361 (1361CN in Canada) or, if using Powerline Carrier devices, ADEMCO 1361X10 Transformer Module Refer to the Programming Overview section for a summary on pager programming. VISTA-GSM Module Note: If using the VISTA-GSM module SNAP TAB UNLOCKED with this control, take signal strength into consideration when CABINET DOOR BOTTOM STEP 1 STEP 2 choosing a mounting location. Refer to the VISTA-GSM Module Figure 1. Installing the Cabinet Lock Installation section for details on signal strength. 2. Remove cabinet door, then remove the lock knockout from the door. Insert the key into the lock. 3. Position the lock in the hole, making certain that the latch will make contact with the latch bracket when the door is closed. When correctly positioned, push the lock until the snap tabs hold it securely. The cabinet can be secured without a lock by using 2 screws in the cover's edge.

    This restriction is due to the capacitive effect on the data lines when quad cable is used. IMPORTANT: Double-balanced zones provide zone tamper protection, and should be used as burglary zones only. Do not use double-balanced zones as fire zones.If enabled (Zone Programming mode, “Hardwire Type” prompt, option “3”), hardwire zones are automatically paired as shown in the table. NOTE: A short across the EOL (i.e., at terminal) on either zone of a zone-doubled pair or on a double-balanced zone causes a tamper condition (displayed as CHECK plus zone numbers).Power Reset: This control does not automatically reset power to 4-wire smoke detector zones, so you must use a relay (e.g., 4204, 4229), or on-board trigger to reset power (also required for fire verification). NOTE: Maximum current on trigger 17 is 100mA. If the smoke detector or thermostat does not trigger again, the control will disregard the first trigger, and no alarm signal will occur. This feature eliminates false alarms due to electrical or physical transients. If used, the maximum number of detectors is reduced to 10 (not standard 16).ULC NOTE: In accordance with ULC standards, the RF supervision period for the VISTA-21iPCN isThe 5827BD and 5800TM can be used in UL Listed Residential Burglar installations. Do not install batteries in wireless transmitters until you are ready to enroll during system programming. After enrolling, batteries need not be removed. If the switchplate is then removed from the wall, the tamper will open, disabling keyswitch operation until the system is next disarmed from the keypad. If the tamper is opened when the system is armed, an alarm will occur.The Ademco 4146 keyswitch is UL Listed.Use the connector harness supplied with the module.Canada: Use the PSC04 Powerline Interface as shown below.The wiring diagram shows the wiring connections that will provide proper operation in most cases.

    To test the integrity of the ground terminal, use a 3-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61-035, or equivalent, available at most electrical supply stores. SA412OXM CABLE 3. Connect the other end of the 2 1 3-conductor cable to the 1361X10 CONTROL Transformer, as shown in Figure 4. BOARD TERMS. Canadian Installations: See Powerline Carrier Device section for Figure 4. 1361X10 Transformer Connections connections to the PSC04 X-10 Interface and trigger pins. 1. Place the 12-volt backup battery in the cabinet. 2. After all connections to the control are completed and AC power has been applied, connect the red and black flying leads on the control board to the battery. Do not attach these leads to the battery terminals until all connections are completed.See Figure 5.Use the Table of Device Addresses to determine the appropriate address for each device. Determine wire size using the Wire Run Chart on the following page. For single 4-wire runs, determine the current drawn by all units, then refer to the Wiring Run chart to determine the maximum length that can be safely used for each wire size. Use supplementary power if the control’s aux.IMPORTANT: Keypads powered from supplies that do not have a backup battery will not function if AC power is lost. Make sure to power at least one keypad in each partition from the control’s auxiliary power output. The battery supplies power to these keypads in case of AC power loss. The battery-backed power supply should have enough power to supply the keypads with the UL required minimum standby power time. Refer to the instructions included with the devices and set each address according to the Table of Device Addresses.The module’s address is internally set to 03 and cannot be changed.The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad conductor cable is used (750 feet if shielded cable is used).

    When the switch is held down, LED 1 (top red LED) will be off, and the other LEDs have the following meanings (see diagram for specific functions): The following is a list of the various Programming modes used to program this system. Most of the data fields in this system have been programmed for specific default values. However, some fields must be programmed for each particular installation to establish its specific alarm and reporting features. Assign zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF transmitters. Program each of the four alphabet function keys to perform one of several system operations. Similar to ?56 mode, but provides a faster programming procedure and is intended for those more experienced in programming controls of this type. Assign device addresses used by 4229 or 4204 Relay modules and map specific relays and device outputs, and assign unit codes for Powerline Carrier devices. Create alpha descriptors for easy zone identification. Create schedules to automate various system functions. Entering Data When the desired field number appears, simply enter the digits required. The keypad beeps three times after the last digit is entered and automatically displays the next data field in sequence. The field’s data is displayed, but no changes can be made.The Alpha display keypad will display the first of a series of prompts. This resets all data fields to the default values shown on the Program Form. Use ?97 only if you wish to return to the original factoryprogrammed defaults. To Initialize Download ID Press ?96 while in Program Mode. This initializes the system for downloading and resets all the subscriber account numbers and CSID. To enter the programming mode if ? 98 was used to exit, you must first power the system down.The system keypad will display a “check” message indicating the appropriate zone (but keypad beeping does not occur).Allows for various custom responses.

    Types 92 and 93 can only be programmed via downloader. UL installations: Zone Types 90 -93 may not be used as fire or burglar alarm zones on fire or UL burglar alarm installations. NOTE: All of the zone types described are available for the wireless portion of the system, if used. Valid entries for each field are shown in italics. Explanations and special notes are presented below the entries. Use the separate Programming Guide to record the data for this installation. Data field programming involves making the appropriate entries for each of the data fields.Fields unique to the VISTA-21iPSIA are indicated by heavy borders and reverse type heading “V21iPSIA” for easy identification. However, the user code is always needed to disarm the system. NOTE: A 0 in either digit disables the phone module. Must be 00 for UL Commercial Burglar Alarm installations. UL installations must be 1 if wireless devices are used. UL installations must be 0 (no forced bypass). See ?29 Menu Mode section for procedures. If a 5827 or 5827BD Wireless Keypad or 5804BD Transmitter is being used, a House ID code must be entered and the keypad set to the same House ID. You can assign RF house ID for each partition. Use zone list 3 to assign these zones (see ?81 Zone List Programming section for details). UL fire alarm installations: must be 1. If 2 selected, ding occurs upon reception of the wireless arming command. UL Installations: must be 1 for UL Commercial Burglar Alarm installations. UL Installations: For residential fire alarm installation, must be set for a minimum of 4 min (option 1); for UL Commercial Burglary installations, must be minimum of 16 min (option 4). Note that if the previous state was armed Away or Stay, the system ignores sensor changes for 1 minute, which allows sensors such as PIRs to stabilize. UL Installations: must be 1 (power-up in previous state) SIA Guidelines: must be 1Common zones use same delay as partition 1.

    Connection to the incoming telco line via a RJ31X jack and direct-connect cord, as shown, is essential, even if the system is not connected to a central station. The 4286 will not function if this is not done and an error signal (fast busy signal) will occur when trying to access the system via the phone. The house phone lines (gray and brown wires) must be wired to the phone module terminals; not to the control terminals. Otherwise, an error signal (fast busy signal) will occur when trying to access the system from an on-premises phone. Refer to the instructions included with the AVS system for installation procedures. The following is a summary. Mounting the AVS Base Unit As shipped, the AVS Base unit board comes pre-mounted on its mounting bracket, which is designed to mount inside the control cabinet. SECURE WITH TWO (2) Refer to the diagram at right. CABINET SYSTEM TIE-WRAP BATTERY b. Slide the mounting plate to the LOOP right so that the plate’s left-hand TANG tang slides under the cabinet’s tieBENEATH MOUNTING wrap loop. PLATE c. Secure the assembly to the cabinet SLIDE ASSEMBLY TO RIGHT UNTIL TANG SLIPS UNDER CABINET LOOP using the two self-tapping screws provided.Wiring the AVS to the Control The AVS Base unit board has several terminal blocks for making connections to remote stations, telephone lines, and to the control panel. The AVS base unit connects to the control’s ECP terminals, with all other ECP devices connecting to the AVS base unit ECP terminals. See the diagram on the next page for specific wiring connections. DIP Switch: Set the address AVS DIP switch to device address 11. IMPORTANT: The AVS should be the only ECP device connected to the control’s ECP terminals. Connect all other ECP devices (keypads, expander modules, etc.) to the ECP terminals on the AVS board.Use ?29 Menu mode to program various internet reporting and supervision options.

    Hardwire Internet Connection: Connect an active Ethernet cable (with RJ45 connector) to the IP connector on the upper left corner of the control board. The control must be registered before internet communication can occur. Refer to the Registering the Control section for details. If an account for the control does not yet exist, please obtain the account information from the central station prior to programming this module. (2) The control must be registered with AlarmNet before normal operation. See Registering the Control with AlarmNet section for registration procedures. When the internet connection is active, the Network LEDs have the following functions:IMPORTANT! This device requires activation of its SIM card. See the SIM Activation Note in the Registering the Control with AlarmNet section later in this manual for the procedure. Mounting the ModuleAvoid performing this installation while standing on a carpeted floor. Carefully align the antenna’s connector over the SMA connector protruding from the adapter plate, then screw it down (clockwise) until it is finger tight. Do not over tighten. Call the AlarmNet Technical Assistance Center. RSSI is a measure of how well the VISTA-GSM is receiving the cell tower. If a consistent RSSI of three bars cannot be found, the control cabinet may have to be moved to an area of better reception. LED 1 (top red LED) will be lit to indicate that the display is in RSSI mode, and the other LEDs indicate signal strength (lowest to highest, from top to bottom) between the module and the receiving tower. If the SIM is not activated, signal strength can be viewed at these LEDs by simultaneously pressing and holding the TEST and STATUS switches on the control board. Status Indicator Switch Press and hold the Status LED Indicator Switch to change the LED functions to view the network carrier status.

    UL installations: For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit time must not exceed 60 seconds. SIA Guidelines: minimum exit delay is 45 seconds If the subscriber does not have “call waiting” and is not using PABX, make no entry in this field. NOTES: 1. The call waiting disable feature cannot be used on a PABX line. 2. Using Call Waiting Disable on a non-call waiting line will prevent successful communication to the central station. Upon entering, the system must be disarmed before the time entered expires, otherwise it sounds an alarm. Common zones use same delay as partition 1. UL Installations: For UL Residential Burglary Alarm installations, must be set for a maximum of 30 seconds; entry delay plus dial delay should not exceed 1 min. For UL Commercial Burglar Alarm, total entry delay may not exceed 45 seconds. SIA Guidelines: minimum entry delay is 30 seconds. Do not fill unused spaces. Sound ends when exit time expires. SIA Guidelines: must be enabled (enter 1)Delays can be selected from 0 to 225 seconds, in 15-second increments. This delay is per message. NOTE: If ?55 is set to “0,” use minimum of 30 seconds to avoid redundant IP report. However, this value may need to be adjusted (ex. 45 secs) depending on the reporting environment. If unsuccessful, the system will make up to 8 attempts to send all reports to the secondary number. If still unsuccessful after the 16 attempts, the system displays the “COMM. FAILURE” message (FC for fixed-word displays). Provides delay of “BURGLARY ALARM” report to the central station, which allows time for the subscriber to avoid a false alarm transmission. This delay does not apply to zone type 24 alarms (silent burglary) or to 24hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent as soon as they occur. See Zone Programming section for procedures. See Function Key section for procedures.

    Select 0 for all other formats. See Zone Programming section for procedures. Entering 0 in the second box advance to the next field. A 0 in the first box disables a report. A 0 in the second box eliminates the expanded message for that report. Use a different digit for each zone until you have used up available digits. If the number of zones exceeds the number of available digits, begin with digit 1 again. This is an “enabling” code only and is not the actual code sent to the Central Station office. Entries in the second boxes are ignored. An entry of 0 in the first box disables the report. If AC restores before the report goes out, there is no “AC LOSS” report. Frequency of report is set in Scheduling mode (event 11) or by the following key commands:The keypad will display “CA” (fixed-word) or “ALARM CANCELED” (alpha display). If the system is not disarmed before entry delay expires, an “EXIT ALARM” message (V21iPSIA: also zone alarm message) will be sent to the central station. The keypad will display “EA” (fixed-word ) or “EXIT ALARM” (alpha display), and alarm sounding continues until the system is disarmed (or timeout occurs). With Contact ID. NOTE: “OPEN” reports are not sent if the associated closing report is not enabled. UL installations: must be enabled if wireless devices are used. See Output Device Programming section for procedures. No message is sent to the Central Monitoring Station. If the system is not disarmed within two minutes, the alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the Central Monitoring Station (after dial delay expires). See Output Programming section for procedures. See Zone List Programming section. Alarm restore signals indicate that respective alarm zone(s) are no longer faulted. Otherwise, alarm restore report(s) for respective alarm zones are sent when the system is disarmed. An Opening report followed by an Armed Stay report is sent to the Central Station.

    If the door is opened and closed within the exit delay period, the system remains in AWAY mode. Any RF device that arms the system AWAY overrides this feature and the system remains armed AWAY. If only one cross zone is tripped during this time, a trouble message (CID code 380) for that zone is sent to the Central Station. Assign cross zone pairs in zone list 4. This option not for use in UL installations. NOTE: Cross zoning takes effect only after Exit Delay expires. Restore Code. UL: must be enabled if wireless devices are used.It can be assigned to zones with sensors that provide a trouble indication when an oil tank is low, or similar applications for critical condition monitoring where a non-alarm response is desired.Automatic Exit Delay Reset occurs only once during an armed AWAY period. Otherwise, the call to the secondary number by the communicator after the alarm report will prevent the AAV from taking control of the telephone line, and the AAV “Listen in” session cannot take place. SIA Guidelines: Exit delay should be enabled. If the log becomes full, new messages overwrite the oldest messages in the log. At any time, the downloader operator can then upload the log and view or print out all or selected categories of the log. The downloader operator can also clear the log. Event log can also be viewed at an alpha keypad. Each partition turns off its own trouble sound. NoExternal sounder will be turned off by normal bell timeout, or by security code plus OFF from either partition (it does not have to be the one that was armed). Entry 2: Selects the desired phone line fault response. Option 2 may be used even if a relay unit or Powerline carrier device is not connected to the control. Partition in ?80 should be set to “0,” for STOP. The fault must be received and annunciated within 200 seconds of its occurrence. SIA Guidelines: Must be set for option 1 or 2.IMPORTANT: Do not press ?

    97 to load defaults if any programming has been done previously—data already programmed into the system will be changed. To enter the programming mode if ? 98 was used to exit, you must first power down the system. Enter the phone number of the downloading computer. Do not fill unused spaces.Refer to the chart below and program accordingly.The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible. To clear entries, press ?160?. To clear entries, press ?167. To clear entries, press ?169?. To clear entries, press ?170. This gives the Central Station enough time to verify the alarm report that it received, before the dialer attempts to dial the pager. This delay is for ALL pagers in the system. To enable the “clean me” feature, a time response setting of “3” (1.2 seconds) must be entered in ?56 Zone Programming for zone 1. To clear entries, press ?163?. To clear entries, press ?164. To clear entries, press ?166?. Contradictory options can cause unpredictable results. UL installations: Do not configure zones as fire alarm or UL burglar alarm zones. Vent Zone (entry 2): Zones set for this option are ignored if faulted when arming the system, but are protected if the zone is later restored (e.g., an open window can be ignored when arming, but if the window is later closed, it will be protected; opening the window again causes an alarm.) Bypass Disarmed (entry 4): Zones set for this option can be bypassed only while the system is disarmed. Bypass Armed (entry 4): Zones set for this option can be bypassed when the system is armed. Faults Display (entry 7): Selects how faults on zones set for this zone type are displayed. Use Entry Delay (entry 8): Selects whether to use the system’s entry delay times. Use Exit Delay (entry 8): Selects whether to use the system’s exit delay time.

    Interior Type (entry 8): Zones set for this option are treated same as standard zone type 4 (bypasses when armed STAY, faults displayed). Alarm Sounds (entry 9): Selects the type of alarms sound for zones set for this zone type. Chime Enable (entry 10): Zones set for this option cause a chime when Chime mode is on. To calculate the value for each entry, add the values of the selected options in each of the entry’s columns shown in the respective chart (one option per column).If none of the codes are suitable, choose a code in the reserved range of 750-789 and make sure to define the code with your central station. NOTE: Use of touch screen devices does not affect the number of standard keypads supported. Entry 2: Enter the desired sound option for this keypad. See ?29 Menu Mode section for enabling Remote Services. See ?29 Menu Mode section for enabling Remote Services. FIXED-WORD KEYPAD NOTE: If using 2-digit display keypads (e.g. 6150RF), do not use exit times greater than the 96-second delay option. Using a longer delay time may cause end-user confusion because 2-digit display keypads cannot display times greater than “99.” If longer exit time is required by the installation, it is recommended that the Exit Time Display option be disabled (“0”). This is useful when using the GOTO partition function. ECP faults will display “1” plus the device address (00-15) of device causing the fault (e.g., faults on device 07 display as “107”). Select “1” if using 2-digit Fixed-Word Display keypads (e.g., certain 6128 series keypads). If selected, ECP faults for all devices will display as “91” on 2-digit displays, and “191” on 3-digit or Alpha keypads. The system can control two independent areas of protection (known as partitions) for use by independent users, if desired, by simply assigning zones to one or the other partition during zone programming. The system, by default, automatically distributes users between the two partitions.