• ademco 6270 user manual

    ademco 6270 user manual

    Download Link: ➡ ademco 6270 user manual



    File Name: ademco 6270 user manual.pdf
    Size: 4827 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 24 May 2019, 15:22 PM
    Rating: 4.6/5 from 809 votes.


    Last checked: 2 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download ademco 6270 user manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    ademco 6270 user manual

    The 6270 will send the time to the control panel every hour. This 1-hour timer starts on 6270 power-up. A checkmark appears in the button when the Chime Mode is “ON”. Press the “HOME” or “BACK” button after making your selection.The “User Options”. The system will save the configuration. When the save is complete, the User Setup screen is displayed with the new user’s name shown. How to Delete a User Delete a User as follows: SCREEN ACTION Three selections are available: add a. The User Setup screen is displayed. How to Edit a User Edit a User as follows: SCREEN ACTION Three selections are available: add a user, edit a user, or delete a user. The “User Options” screen is displayed. Note: The authorized code for deleting, adding, and editing users is dependent upon the alarm panel you are interfacing with. Check your alarm panel Installation and Setup Guide to determine who can delete, add, and edit users. How to Clean the 6270 IMPORTANT: Do not use an abrasive cleaning agent or abrasive cloth when cleaning the 6270 or damage to the touch screen may occur. Clean the 6270 as follows: 1. A pop-up window displaying “Touch Screen will be disabled so that you may wipe the screen clean. Do not slam sensor-protected doors or windows. Keep dust from accumulating on the keypad and all protective sensors, particularly on motion sensors and smoke detectors. The keypad and sensors should be cleaned carefully with a dry soft cloth. There are a total of three diagnostic tests. How to Access the Diagnostics To access diagnostics, do the following: 1. The Enter Authorized Code: authorization screen is displayed. All or any individual test may be run when you access the Diagnostics screen; however, each test must be performed one at a time. Summary of Connections. With clear, simple controls on a touch-screen interface, the entire family will find the 6270 both easy to learn and easy to use. As a security and home-automation interface, the 6270 may be used.

    • ademco 6270 user manual pdf, honeywell 6270 installation manual, ademco 6270 user manual, ademco 6270 user manual pdf, ademco 6270 user manual download, ademco 6270 user manual instructions, ademco 6270 user manual free, ademco 6270 user manual pdf.

    The 6270 can be used for: Quick and easy security system operation Messages Control of the home environment, including lights and contains provisions for the future control of heating and air-conditioning. This may be caused by and incorrect ECP address in the 6270 or because AUI type devices have not been enabled in the panel. While this message is being displayed, you must use the 6270 default code of “4140”. The 6270 must be used in conjunction with a second keypad that is powered by the control panel. Use a Listed Class 2 power supply suited for the application. Hang the case front on the holding clips as shown in Figure 2. Attach the top of the case first, and then press the bottom section inward until it snaps into place securely. If disarmed, faults or troubles are present. Front Panel Buttons BUTTON. If this is a first time power-up of the unit, follow the initialization procedure in this section. The “Arming” screen is displayed. SCREEN ACTION 2. Press the MORE CHOICES button. The “More Choices”. Note: If the top of the screen is displaying ECP Error, the ECP address in the 6270 is not valid for the panel that it is connected to. To change the ECP address in the 6270 when ECP Error is being displayed, enter the 6270 default code of “4140”. Press the OK button to accept the address setting or the CANCEL button to maintain the original ECP address. A checkmark appears in the button with the Lighting option is “ON”. Press the DONE button to accept the setting.Press the Ok button to accept the setting, or press the Cancel button to cancel your selection.How to View the Panel Configuration The Panel Config button displays a screen that contains the configuration of the panel that the 6270 is connected to. To view the panel configuration, do the following: SCREEN ACTION 1. You may also select the time interval that must pass prior to the 6270 going into screen saver mode (screen goes blank).To select the. When the time is set it will be stored in the 6270 only.

    If you return after an alarm has occurred and the main sounder has shut itself off, the 6270 will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. Ask your system installer if emergency messages are available on your system. The Emergency screen cannot be accessed while running a diagnostic test. The control panel must be programmed to record various system events in installer programming mode. The system can be programmed to lock the keypad display with the first zone that produced an alarm. Ask your installer if your system has been activated with this feature. Users for the system are programmed in a central user setup location that provides the specific questions for authorization levels assigned to different users. The User Setup screen is displayed. Press the SAVE button. The system will save the configuration. When the save is complete, the User Setup screen is displayed with the new user’s name shown. The configuration changes are saved and you are returned to the User Setup screen. Console Emulation Mode Console Mode allows you to use a 6270 interface just as you would a regular system keypad. All commands shown in Console Emulation mode can also be executed from a standard alpha keypad. All messages will be lost if the 6270 loses power or if it is reset. Voice messages are recorded and retrieved using the “Message Center” screen. The below illustration identifies the various areas and buttons on the “Message Center”. External One Short Beep a. MESSAGE LED is yellow, ARMED LED is red, and READY LED is green. Each LED's on and off state has different meanings as described below. You may also select the time interval that must pass prior to the 6270 going into screen saver mode (screen goes blank).When the time is set it will be stored in the 6270 only. This 1-hour timer starts on 6270 power-up.

    This is the 6270’s main default screen (starting screen) and is the first screen you will see when the 6270 is powered up and initialized. It is from this screen that you will select from the main menu. ITEM FUNCTION AWAY Press this button to arm when no one will be staying on the premises. When the Arm Multi-Partitions circle does not contain a check mark, each partition must be armed individually. Press this button for more Security, Lighting, and 6270 setup MORE CHOICES. Monitoring is accomplished with various contact and motion sensors for perimeter and interior burglary protection, plus the system may have strategically placed smoke, heat, or combustion detectors. Alarms When an alarm occurs, the 6270 (and any other keypads) and external sounders will sound, and the zone(s) causing the alarm are displayed. If your system is connected to a central monitoring station, an alarm message will also be sent. Extended Functionality Extended functions are advanced functions that can be accessed through a standard alpha keypad or through emulation mode on your 6270 touch screen. Refer to your Control Panel User Guide for these features. The following table lists the three different arming modes and the results of each. FEATURES FOR EACH ARMING MODE Arming Exit Entry. The 6270 beeps twice (Away and Night Maximum Modes) or 3 times (Stay and Night Instant Modes) a DISARM button appears a text message appears stating. Note: A user may have access to some (but not all) of the available partitions. You have two arming options: To arm one or more partitions, highlight the partition(s) to be armed by touching it on the screen, then press ARM. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. The system will not allow you to bypass fire or emergency zones. Note: A zone cannot be unbypassed while the system is armed. Enter your 4-digit user code.

    U L The home lig hting feature ha s not been evaluated by UL. The backgrou nd and buttons shown on the “ Home ” screen in this manual are for example onl y. Your system installer may ha ve changed the actual b ackground and buttons shown on your “ Home ” screen. Below screen Displays Emergency functions (as programmed b y your installer. Below screen For future use. To the right of screen Use to scr oll up throu gh lists di splayed on t he sc reen. To the right of screen Use to scroll down through lis ts displayed on t he sc reen. ITEM FUNCTION AWAY Press this bu tton to arm when no one will be staying on th e premises. W hen armed in AWAY, the system will so und an alarm if a pro tected door or w indow is opene d, or if any movement i s detected in side the premi ses. You may leav e through the entr ance door duri ng the exit dela y period withou t causing an alarm. You may also re-enter thro ugh the entran ce door, but mus t disarm the syst em with your User C ode within the entry del ay period or an a larm will occ ur. STAY Press this bu tton to arm when you are staying home, but mig ht expect som eone to use the entrance door la ter. When armed in STAY, the syst em will sound a n alarm if a protected door or window is o pened, but you may otherwise move freely throughout the pr emises. Lat e arrivals can enter through the entr ance door wit hout causing an alarm, but they must disarm the system within the entry delay period or an alarm will oc cur. NIGHT Press this bu tton to arm when you are staying home and do not expect any one to use the e ntrance door.When Multi-Part itions is ch ecked, all p artitions within t he system ca n be armed at on e time (if the user i s so authorized). When the Arm M ulti-Partition s circle does not contain a che ck mark, e ach part itio n mus t be armed in div idu ally. MORE CHOICES Press this bu tton for more Sec urity, Lighting, and 6270 setup features.

    When the chime mode is selected, a request is sent to the alarm panel requesting that the panel chime the 6270 whenever a change in zone status occurs. A checkmark appears in the button when the Chime Mode is “ON”. Press the “HOME” or “BACK” button after making your selection. When the 6270 exits the “Operating Modes” screen, your selection is saved. A pop-up window displaying “Touch Screen will be disabled so that you may wipe the screen clean. Please use a damp, soft cloth. DO NOT use any liquids, sprays, or ammonia-based cleansers. The 6270 will return to this screen with the “Home” button is pressed or when an entry is not received for a pre-set period of time. Master Code: A 4-digit code that gives users access to all of the system’s functions, including the ability to program other users in the system. This securit y system offers you burglary protection a nd may provide fire and emergency prot ection. To rea l ize the full potential of the syst em, it is import ant that you feel comfort able operat ing it. U L The home lig hting featur e has not been ev aluated by UL. Y our system may als o have been programme d to auto matic ally tr ansmit alarm or sta tus me ssage s over the phone lines to a central al arm monitoring station. The 6270 Interf ace The 6270 is an in tuit ive, g raphical interface that combine s security and optio nally, h ome light ing con trol. With clear, simple controls o n a touch- screen in terface, the en tire family w ill find th e 6270 both e asy to learn an d easy to u se. As a security and home- automation inte rface, the 6270 may be use d for: Quick and ea sy security system operation Home lighting control On ce you have made your selection, you will n avigate th rough various s u b-menus by touching but tons or icons to perform the function you desi re. From t his screen you can: access m ess age s control your security system, and opti onally, control th e premises lighting.

    Note: This will n ot occur if an y zone(s) i s open (not r eady). If you ret urn after an alarm has occurred and the main sounder has shut its elf off, the 6270 will b eep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY an d CONTACT T HE POLICE fro m a nearby s afe location. The system w ill disarm.Note: If you w ish to disarm on ly selected partitions, you must first h ighlight the partition( s) to be disarmed, t hen press the DISARM SELECTED button. This tim e is selecte d on the “ Setup ” scre en. Eac h 6270 and oth er keypad is as signed a defa ult partition for di splay purposes, and wi ll show o nly that p artit ion's info rmation. For example, if your phys ical site is a four-apartment hous ing unit, your alarm s ystem may be configured with f our partitions.Note: A code ma y have acce ss to some (but not all) of the availabl e partitions. This scr een display s the available partitions (i n this case, Part itions 1, 2, a nd 3), and their c urrent status. The current part ition is shown at the top of the display (in this exam ple, the devic e is attached to Part ition 1 ( P1 )). To ch ange this assignm ent, select the appropriate button (e.g. pre ss P2 to swit ch control t o Partition 2). As k your system in staller if emerg ency messag es are available o n your system. The Emergency s creen cannot be ac cessed while ru nning a diagnost ic test. An emergency mess age for panic or fire can be sent to the central monitoring s t ation from the Emergency screen. Once the Emergency screen is accessed, perform t he following to send an emergency mess age. SCREEN ACTION On the Emerge ncy screen pre ss and hold (for at least 2 seconds) the a ssociated alarm button f or the type of em ergency message y ou want to se nd ( FIRE, PANIC, or MEDICAL ). You a re immediatel y returned to the screen from which yo u pressed the “ PANIC ” button.

    The control panel mus t be programmed to record various system event s in installer programming mode.Note: When All Partitions or All Events button is pre ssed, and more th an 100 events exi st, the Show More button text will chan ge to read Next 100. An interru pted sound will also be pro du ced by optio nal e x t e r i o r s o u n d e r s. A F I R E m e s s a g e w i l l a p p e a r a t y o u r k e y p a d a n d remain on u ntil you si lence the alarm. Silencing a Fire Alarm 1. Silenc e the al arm by en ter ing yo ur cod e and p ressing th e OFF key. To clea r the alarm from the di splay, enter your code and press th e OF F ke y again. 2. If the keypad do es not indicate a READY condition after the second OFF sequence, press the READ Y key to displ ay the zone( s) that are faul ted. Be sur e to ch eck tha t smo ke de tecto rs are not res ponding to smoke or heat producing ob jects in their vicinit y. In this c ase, elimina te the source of heat or smok e. 3. If this does not remedy the problem, there ma y still be smok e in the detector. Clear it by fanning the det ector for about 30 seco nds. 4. When the prob lem has been corrected, clear t he display by entering your code and pres sing the OFF key. The sy stem can be programmed to lock the keypad display w ith th e first zon e that pr oduc ed an alarm. Ask you r installe r if yo ur syste m has been activa ted w ith thi s fe ature. Also the “A ”, “B ”, o r “C ” key may be programmed t o scroll the keypa d display t o view the previous or sub sequent fire alarms. Users for the syst em are programmed in a central user s etup location that provides the specifi c questions for authorizati o n levels as signed to different us ers.The “ Us er Optio ns ” screen is di splayed. Note: The authorized cod e for adding users i s dependent upo n the system you have. Check wi th your system install er to determine who can add users. 3. Press t he box next to Ent er User Name. The Enter Data ke yboar d scre en is disp layed.

    Monitori ng is accomplished with vari ous contact and motion sensors for perimeter and interior burglary protection, plus the system may ha ve strategicall y placed smoke, heat, or comb ustion detectors. Your system provides th ree modes of burglary protection: Away, Stay, and Night, and even a llows you t o “ by pass ” selected zones of prot ection while leaving t he rest of the s ystem armed (e.g. thi s enables you to a rm the syst em but leave upper-s tory windows open.) The sys tem also provides a C hime mode, for a lerting users t o the opening and closing of do ors and windows ev en while the s ystem is disarmed. Partitions This sy stem m ay be co nfigu red to arm an d d isarm mo re than o ne area, ea ch as if it had its own control. These areas are ca lled partitions. Parti t ions are used when the us er wants to disarm certain areas while leaving o ther areas arme d, or to limit access to certain areas to s pecific individuals. Each user of the syst em can be authoriz ed to operate all or only s ome partitions, an d can be given differ ent priv ilege s in each. Informatio n about Par tition s is presen ted late r in th is doc ume nt. Th ese nu mbers will appe ar on the displa y, along with an alpha descri ptor for that zone (if programmed), when an alar m or trouble condition occurs. Exit delay begins immed iately after e nterin g any arming command, and appl ies to all modes of a rming protection. I f programme d, a slow beeping will soun d throu ghout the ex it delay period. Entry delay gi ves you time t o disarm the sys tem when you reenter through the des ignated entrance door. B ut the syst em mu st be disarmed b efore the entry delay period ends, or an al arm will occur. The keypad wi ll beep during the entry del ay period, reminding you to disarm the sy stem. As k you r installer about the de lay time s programmed into your s ystem.

    Alarms When an alarm occurs, the 6 270 (and any ot her ke ypads) and extern al sound ers will so und, and the zo ne(s) cau sing th e alarm are displayed. If your s ystem is connected t o a central monitoring s tation, an alarm message will a lso be sen t. To stop th e alarm soun ding, simply d isarm the syste m. Memory of Alarm When an alarm condition occurs, the number(s) of the zone(s) t hat caused th e problem are displayed, along with the type of ala rm. These remain dis played until cleared by disarming t he system. Fire Protection The optiona l fire protection porti on of your security sys tem (if used) is always on an d wi ll soun d an alarm if a fire co nditio n is de tected. Users for the sys tem are programmed in a centra l u ser setup loca tion that prov ides the sp ecific qu estions f or autho rizatio n leve l, partition assignme nt, and R F butto n assig nment. Extended Functionality Extended functions are advanced functions that can be accessed through a stan dard alpha keypad or through emulation mode on your 6270 touc h screen. Refer to your Co ntrol Pane l User Guid e for th ese features. The following table lists the three different arming modes and the res ults of each. How to A rm the System Arming the s y stem in any mode is performed i n the same way, as described bel ow. Note: Close all perimet er windows and doors before arming.Note: A user may have access to some (but not all) of the availabl e partitions. You have tw o arming option s: To arm one or m ore partitions, highlight the partition( s) to be arme d by touching it on the scree n, then press ARM SELECTED. Press ARM ALL t o arm all availab le partitions. The system will not allow you to bypass fi re or emergency zones. To bypass zones, the system must be disarmed first.I f the syste m is disar med an d a z on e is byp asse d, yo u can remove the bypass as follows: SCREEN ACTION 1. View bypassed zones by pr essing the SHOW ZONES button.Enter your 4-dig it user code.

    The “ User Options ” scr een is d isplayed with the user ’ s name and cod e displayed. 7. Select the partitions and acces s level for this user. If this user is to be able to Arm and Disarm from ot her partitions, t ouch this box. Th e “ User Options ” scre en is displayed w ith the user ’ s name, number, and code di splayed. 10. If this u ser is assigned a n RF button zone, touch the box below the RF Button Zone. E nter the RF Butt on Zone number. The User Optio ns screen w ill be redisplaye d. Press the SAVE butto n. The system will sav e the configurat ion. When the save is com plete, the User Setup s creen is displa yed with the n ew user ’ s name shown. The “ Us er Optio ns ” screen is di splayed. Note: The authorized cod e for deleting users i s dependent upo n the system you have. Check wi th your system install er to determine w ho can delete users. 3. Press the a ppropriate butto n. The User Setup scr een is displayed. The “ Us er Optio ns ” screen is di splayed. Note: The authorized cod e for editing users i s dependent upo n the system you have. Check wi th your system install er to determine who can edit users. The c onfiguration ch anges are saved and you are returned to the User Setup scre en. To use feature s not supp orted by the 6270, ref er to y our Con trol Panel U ser Guide. Console Emulation Mode Console Mod e allo ws y ou to use a 6270 inte rface ju st as y ou w ould a regular syste m keyp ad. All co mmands shown in Console Emulation mode can also be ex ecuted from a st andard alp ha ke yp ad.The number of messa g es is not limit ed howe ve r; the total tim e of all me ssage s adde d tog ethe r cann ot exce ed 127 second s. Note: The vo ice message s are stor ed in the memory o f the 6270. All messages will be lost if the 627 0 loses pow er or if it is rese t. Voice mess ages are recorded and r etrieved usi ng the “ Message Center ” scree n. The be low illu stration identif ies th e vario us areas and butto ns on the “ Message Center ” s creen.

    When the e nd of the message is reached, the playbac k will stop. 3. To listen to the next me ssage, press the Advance On e Message and Play button. 4. If you w ish to delete m essages, press the Delete button. Th e “ Del ete Memo ” screen wi ll be display ed. You can pres s the Del Select ed button to delete only the currently se lected mess age and return to the “ Messag e Center ” screen, Del All button to dele te all messa ges and return to the “ Mess age Center ” scree n, or the Cancel button to return to the “ Message C enter ” screen wit hout deleting any messa ges. 5. To exit, d epress the BACK or HOME button and the “ Home ” screen will be displa yed. One Beep (every 60 sec.) Keypad only Low battery at a transmitter LO BAT displa yed with descri ption of transmitter. Two Short Beep s Keypad only Arm Away or Maxi mum ARMED AWAY or ARMED MAXIMUM is displ ayed. Red ARMED indicator i s lit.NOTE: On so me syste ms you may also receiv e an audi ble no tificatio n of a syste m batte ry f ailure. C heck w ith yo u syste m installe r to se e if this not ificat ion applies to y our sy stem. MESSAGE LED is yellow, ARM ED LED is red, an d READY LED is green. Each LE D's on and off st ate has differ ent meanings a s described bel ow. If disarmed, fa ults or troubles are present.The “ Advanced Setu p ” button will o nly be active if enabled b y your system in staller. Ask yo ur system inst aller to exp lain the opti ons provided by this button if it is enabled.CONTRAST SLIDE BAR INDICA TOR 6270-006-V0 Touch Screen Contra st Control V OLUME SLIDE BAR INDICA TOR 6270-007-V0 6270 Volu me Control A pop-up wind ow displaying the time period options is displa yed. 2. Select the t ime period opt ion you want by pressin g it. The pop- up window cl oses automatica lly and the se lection is displayed in b lue.Remember New S ettings? “ Select Yes to sav e the change or No to discard the change.The 6270 will send the time to the contro l panel e very hour.

    Thi s 1-hou r timer starts on 6 270 powe r-up. If Adjust for DST (Dayli ght Sav ing s Time) is sele cte d, the 6 270 will adju st fo r Dayligh t Savin gs time. Whe n selecte d, the next time the 1- hour time r expire s, the ne w value will be sent to th e control panel. IMPORTANT: Th is me ans th at the 627 0 settin g w ill ove rride and ove rwrite the con trol pane l time se tting. That i s, if the co ntrol pan el is set to DS T and ad justs but the 6270 i s not, u pon th e 1-h our time r expiratio n, the con trol panel w ill be upd ated to the current time that is not adjuste d fo r DST.When the chi me mode is selected, a req uest is sent to t he alarm panel requesting that the panel ch ime the 6270 w henev er a change in zone status occurs.Press the “ HOME ” or “ BACK ” button after making yo ur selection. W hen the 6270 exits th e “ Operating Mode s ” screen, your selection is sav ed. A pop-up wind ow displaying “ Touch Screen will be disable d so that you may w ipe the screen cl ean. DO NOT use a ny liquids, sprays, or am monia-based cleans ers. Press CONTINU E to disable touchscreen. During these 30 se conds the t ouch screen should be wiped c lean of fingerpr ints using a m ild soap soluti on and a soft c loth. When the counter reach es zero, the w indow automatica lly closes a nd the touch s creen is active. Note: Do not sp ray cleaning agent directl y on the scree n, spray it on clot h then wipe surface area. Routine Care Treat t he components of your securi ty syste m as y ou wo uld any other electri cal equipment. Do not slam sens or-protected doors or windows. Keep dust from accumul ating on the k eypad and all protect ive sensors, p articula rly on mo tion sens ors and smoke detectors. The keypad a nd sensors should be cl eaned carefully with a dry s oft cloth. Do not spray water or any o ther flu id on t he units. However, even i n a “ disarmed ” stat e, “ emergency ” and “ fire ” portio ns of y our sy stem are st ill oper ational.

    Bypass: To intentionally leave a specif ic zone unprote cted wh ile the rest of the sy stem is arme d. Console Emulation: Console Mode allows yo u to use a 6270 interface jus t as you would a regular system keypad. All commands shown in Cons ole Emulation mode can als o be executed from a standard alph a keypad. Delay Zone: A n area of protecti on containing doors most frequently used to enter or exit (typi cally, a front door, back door, or door from the garag e into th e build ing). Th e de lay zone allows suff icient t ime for authorized ent ry or exit wi thout causing an alarm. Consult your installe r fo r the en try and e xit de lay time s that hav e bee n set fo r your syst em during installation a nd record them on the sepa rate sheet prov ided in this guid e. Home Screen: Th e scre en that is n ormally d isplay ed o n the 6270 when e ntries are not being mad e. The 6270 w ill retu rn to this scre en with the “ Home ” button is press ed or when an entry is not received for a pre-set peri od of time. Keypa d: This is th e device through which you o perate your sys tem. It contai n s numbered pushbutt ons similar to those on telephones or calculat ors. These k eys control the armi ng or dis arming of the system, and perform ot her functions that were previously des cribed in this manu al. Maste r Code: A 4-d igit cod e that g ives u sers ac cess to all of th e system ’ s function s, in cludi ng the ability to pro gram other use rs in the system. Se e also “ User Code. Messages Butt on: A button on the Home screen tha t allows you to record and retrieve voice mes sages. Night: An arm ing m ode fo r the sy ste m. Yo ur sy ste m ins taller set the type of arming a nd the zones armed when usi ng this mode. Partition: An independe nt group of zones t hat can be armed and disarmed wi thout affecting other zones or us ers. User C ode: A 4- digi t code that g ives u sers acc ess to th e syste m ’ s basic funct ions. See also “ Master C ode.

    ” Zone: A specific protect ion point (e.g., door or wind ow). Sell er shall have no obl igation under this warranty or otherwise if the product is altered or improperly repaired or serviced by anyone ot her than the Seller. In case of defect, contact the s ecurity profess ional who installed and maint ains your security equipment or the Seller for product repair. This one year Limited Warrant y is in lieu of all other ex press warranties, obligations or liabilitie s. THERE AR E NO EXP RESS WARRAN TIES, WHIC H EXTEND BEYOND TH E FACE H EREOF.Seller does not represent that the product may not be compromised or circumvented; that the product wi ll prevent any pers onal injury or property loss by burglary, robbery, fire or ot h- erwise; or that the product wil l in all cases provide adequate warning or protection. B uyer understands that a properly ins talled and maint ained alarm m ay only reduc e the risk of a burglary, robbery, fire or other events occurri ng without providing an alarm, but it is not insurance or a guarantee t hat such will not occur or t hat there will be no personal injury or property loss as a result.No increa se or a lteratio n, writte n or ve rbal, to this wa rran ty is au thorized. The Honeywell 6270 hardwired alarm keypad makes it easier than ever for you to take advantage of all of your security system's features. Even the most advanced functions are a snap with graphics and menu driver prompts guiding the user every step of the way. The intuitive graphical touchscreen display provides easy centralized control for a variety of daily tasks for systems in homes or businesses. It also keeps you in touch, with a built-in message center that lets you record and playback messages for friends or family members. The 6270 TouchCenter conveniently displays the most recent actions involving system use. A press on the touchscreen is all it takes to access the.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :